Field measurements were made during the heating season to compare IAQ between an air– conditioned building (Building A) and a naturally ventilated building (Building B) situated in the centre of Pyongyang and similar in architectural design, number of occ
Air change rates, indoor radon and carbon dioxide levels were monitored in a lecture theatre in the Hong Kong University of Science and Technology. Two preliminary measurements (Cases 1 and 2) and one series of demand control ventilation simulation (Case 3) were made to investigate the indoor air quality of the lecture theatre. Radon and carbon dioxide levels were found to be relatively high in Case 1 and later improved at the expense of operating the system catering for maximum occupancy in Case 2.
The improvement of air quality due to self-restricted air consumption in regions as well as globally appears to have considerable promise. Self-restriction means the normalised air (energy) consumption reasonable for favourable conditions of life and work. It will allow the use of the compensation concept when the consumption is higher than normal. This method enables us to select environment-friendly means of energy production as well as consumption taking into account the peculiarities of regions.
In a cold climate such as of Montreal the air infiltration through the exterior envelope of a house has a significant impact on the heating energy consumption and cost. Although the reduction of the air infiltration rate to the level of new well-built houses can lead to the reduction of heating energy cost, the present cost-effectiveness of its implementation in the existing houses is low. The evaluation of the environmental impact of this energy conservation measure is performed using the GWP (Global Warming Potential) index.
Three buildings are investigated to study the indoor air quality and the impact of the outdoorair pollution. These buildings, a swimming pool, a school and a nursery are located in anurban area. So, during experimental studies, typical outdoor and indoor pollutants such ascarbon monoxyde, nitrogen dioxyde, carbon dioxyde, and total volatile organic compoundsare monitored. Also, the relative humidity and the temperature are carried out. The analysisallows us to reveal several points.
Chinese food is delicious. There are many kinds of cuisine. But the stir-fry, fry and deep-fry produce a large amount of steam and smoke which cause indoor air pollution seriously. So it must be controlled. The paper gets some flow distribution regularity of steam and smoke current in Chinese cooking by testing in laboratory and advances a new method to prevent the diffusion of smoking current-kitchen hood with forced air screen. By comparing with other removers, the equipment can save heat (cold) load and improve indoor air condition greatly.
Rooms with high windows are likely to have comfort problems caused by cold airdowndraught, which are usually solved by placing heating appliances underneath thewindows. In the city of Zug, Switzerland, a highly insulated educational building with aconcrete core system for heating and cooling is planned. The purpose of our investigation wasto find out whether any measures are necessary in this building to compensate the effects ofdowndraught in the occupied zone. Special attention has been paid to the effect of passivemeasures like air flow obstacles or openings in the window sill.
The U.S. Environmental Protection Agency (EPA) in partnership with the NationalAssociation of Energy Service Companies (NAESCO) is demonstrating an approach whichintegrates indoor air quality (IAQ) improvements into energy efficiency upgrades provided toschools using performance contracts. Capital costs of energy-related improvements arefinanced, then repaid from utility and maintenance savings realized as a result of newequipment, systems, and controls. In five public schools in various climate zones across theU.
The Netherlands Agency for Energy and the Environment(NOVEM) is conducting a program for the implementation of Low Temperature Heating (LTH) systems in buildings. The primary goal is to enable the use of Low Talued Energy as a heating source. Major savings in enery consumption can be realised by fully utilising the potential of Low Valued Enery. Besides the argument of savings in energy supply, there are additiond benefits in the fields of. Indoor Air Quality (particles, mites, lower air temperature, annoyance and dust);.
The energy saving practice of stopping ventilation systems at night may reduce the daytimeair quality. Sorption phenomena where pollutants absorbed at night are reemitted during theday and the general slower removal of pollutants at the reduced average ventilation rates willcontribute to the deterioration of air quality at intermittent running systems. The purpose ofthe study was to investigate the impact on construction product emission during the day fromreduced ventilation rates at night. Experiments were performed in three small-scale chambersof Climpaq type with dilution systems.