Building envelope and conditioning unit interaction: a case study.

The building may be seen as a "container" of a conditioned environment where man comfortably carries out a number of activities. The achievement of acceptable indoor environmental conditions depends on the way such a container is realized. In other words, the whole building, which is designed to create a space in which man can suitably carry out certain activities, contributes with all its parts to controlling the desired environmental conditions.

Large office buildings, what are the dominant parameters for energy consumption?

The thermal behaviour of an office building is presented and discussed, as well as the results of a sensitivity study, which analyses the impact of architectural decisions and the effect of occupancy in terms of energy consumption (cooling and heating loads). This study was carried out using one floor of an office building, with large glazed facades, recently built in S. Paulo in Brazil, which was monitored for a short period (11 days)]. This building has been used as reference, for the sensitivity studies carried out for two climates, S. Paulo in Brazil and Lisbon in Portugal.

Torre Guil environmental educational centre, Murcia, Spain. Proposal for energy saving and demonstration.

The buildings of this Environment Educational Center, designed with innovative energy saving features, minimize the impact on the preexisting environment. Renewable energy concepts have been applied to the building design, and intelligent control of lighting and air-conditioning has been included. Most of the buildings are green roof underground buildings, where domes that allow spans up to 42 m have been designed. Average energy saving is over 70% on heating and cooling demands and 60% in lighting.

Design of the built environment: its impact on energy demand and consumption in Saudi Arabia.

Although Saudi Arabia empowers the world with energy, the country is faced with unprecedented demand on electric energy. The issue, however, is neither affordability nor shortage but the exponential growth of demand on electricity, which reached an annual rate of 17% [Ministry of Industry and Electricity (MIE), 1995). This figure indicates that we need to double the number of our power generation plants within few years in order to meet the kingdom's present and near future demand.

Airflow and wind pressure around a full-size cubical building model in a wind tunnel: basic data for developing a quantitative tool for cross ventilation design.

A new research project in the Building Research Institute aims at developing a quantitative tool for cross ventilation design for buildings. One of the approaches adopted in the project is the experiment in the wind tunnel, where a full-size cubical building model can be used at this stage. In this paper, mainly the first observation result for the building model without openings is shown and discussed.

The use of bioclimatic principles and geothermal energy sources in designing the hotel "Ana" in Kanjiza Spa.

The detailed urban plan of Kanjiza beside the two existing hotels at the grounds assigned for the development of the Institute of Special Medical Rehabilitation "Kanji"a Spa" comprises a plan to build a third hotel. An urbanistic solution of the complex was found, (positioning of the hotel) based on a bioclimatic study in which bioclimatic elements both in the analysis of the location and in the architectural design were taken into account. The bioclimatic study started by considering the elements of climate and the conditions of the location.

A case study on global-conscious and local-oriented housing design in a hot and humid climate. Part 2: evaluation of the thermal environment in indoor and semi-outdoor spaces.

In order to confirm the effectiveness of the indoor climate control system adopted in the experimental house, the indoor climate in summer was evaluated for the experimental house and two other buildings in Nanning city and a comparison was made. Two vernacular buildings which have natural indoor and semi-outdoor cooling systems were selected for the study The majority of the measurements were taken using the spherical thermography system. The results showed that the quality of the indoor thermal environment of each building is approximately the same.

Problems with descriptive energy efficiency standards (NZS4243:1996).

This paper presents a synopsis of the content of the New Zealand Standard for Energy Efficiency in Large Buildings. This new standard is purported to be 'descriptive'. The paper outlines the three permissible methods for demonstrating compliance with the Standard's requirements. Disadvantages of this approach are stated and an alternative proposal is suggested.

Risk of indoor condensation related to thermal insulation standards.

Condensation phenomena on internal surfaces of buildings are becoming recurrent eventualities in contemporary buildings, particularly in residential buildings. Despite the general belief, this accumulation of water on walls is not mainly due to mass migration from outdoor to indoor, but to a modification of behavioural approaches of people, especially referring to the preferred air temperature.

Pages