Extension of the kinetic energy model for calculation of the zone average air velocity

The aim of this work was to develop a new calculation method of the zonal air velocity in ventilated room during the design stage. The verification showed a good correlation between the method and the experimental data.

Improved prediction of heat transfer in horizontal thermally unstably stratified boundary layers by resolution of the large-scale buoyant structures.

When using RANS turbulence models the mean profiles of mixed convection can be predicted with accuracy. It is more important to resolve large scale 3D structures instead of using very complex turbulence models, for the prediction of room airflow with floor heating or cooled ceiling.

Simulation tool for indoor air quality improvement in a covered swimming pool

This study consisted first in a sampling campaign that has shown the important levels of NCL3 encountered in swimming pools. Then a simulation of the NCL3 dispersion was conducted wtih the following simulation tools : TRNSYS (thermal simulation) and FLUENT (CFD simulation).

Use of predictive ventilation to evaluate the emission rates of pollutant sources in an enclosure and to reconstruct the associated concentration field

This paper presents a numerical method aiming at recreating the concentration field of a pollutant at each point of a ventilated enclosure that contains one or several pollutant sources of unknown emission rate.

Numerical analysis of normalized concentrations in the occupied zone for various office ventilation systems.

Flow, temperature field and contaminant concentration distributions are analyzed using CFD for 5 different ventilation systems.

Numerical modelling of particle dispersion within a displacement ventilation system

This paper deals with a 3D numerical study to assess the effectiveness of a displacement ventilation system to remove particulate pollutants, generated in the occupied zone of a room.

Lärmbekampfung in RLT-Anlagen, Teil 2 Noise reduction in ventilation systems, part 2

The methods for estimating or calculating the noise reduction in ductwork are described. Information is given about noise propagation in straight circular or rectangular ducts and in ducts with diameters changes, bends, elbows or junctions. Noise reduction by air diffusers, filters, coils, is also presented, as well as noise emission by ducts walls.

Making the case for IAQ

The article summarizes the results of three recent Danish studies showing that the improvement of air quality in offices increases productivity by 5% or more. It also mentions a recent Danish study about the annual benefit of improved air quality, which was found as being at least ten times higher than the increase in costs.

Ventilating multiunit residential buildings

Ventilation strategies for multiunit residential buildings are described according to the results of a survey in 260 randomly selected buildings in Canada. Most buildings use corridor pressurization systems with an either central or apartment-based air exhaust. Some outdoor air is delivered to individual apartments, but in some cases, corridor air systems act as a ventilation system for individual apartments. Occupants complaints have been recorded, the main one being odor transfer between apartments.

New requirements of standard 62-2001

This article presents the new requirements of the ANSI/ASHRAE standard 62-2001, Ventilation for Acceptable Indoor Air Quality, including recent changes of the standard available at the Ashrae web site. It explains the status of the 31 addenda to the 1999 version of the standard, some of them being included in the 2001 version, others being still in discussion or in the process to be adopted.