Heat pumps in compact ventilation appliances for solar passive houses - Part 2 Kompressionswärmepumpen inLüftungs-Kompaktgeräten für Solar-Passivhäuser - Teil 2

Compact ventilation appliances appeared on the market for solar passive houses. They include a heat pump to transfer heat from ventilation exhaust air to fresh air and/or domestic hot water. This article is the second part of a serie of two. It continues to describe a model for simulating the operation and performance of such appliances which was developped to be used in the TRNSYS software environment. It compares the results of calculations with those of laboratory measurements.

Heat pumps in compact ventilation appliances for solar passive houses - Part 1 - Kompressionswärmepumpen inLüftungs-Kompaktgeräten für Solar-Passivhäuser - Teil 1

Compact ventilation appliances appeared on the market for solar passive houses. They include a heat pump to transfer heat from ventilation exhaust air to fresh air and/or domestic hot water. This article describes such systems and gives information about a model for simulating the operation and performance of such appliances which was developped to be used in the TRNSYS software environment.

Influence of temperature and humidity on the perception of odours Einfluss von temperatur und Feuchte auf die Wahrnehmung von Geruchsstoffen

Experiments were operated to estimate the influence of temperature and humidity on the perception of odours in the air by trained and untrained persons .

Mechanical ventilation in the new german regulation EnEV 2002 Maschinelle Wohnngslüftung vor dem Hinter-grund der Energieeinsparverordnung 2002

This article compares the requirements for mechanical ventilation systems in the new German regulation on energy savings (EnEV 2002) with those contained in the previous regulation (named WSchV 1995). It also gives information about the way to test and certify mechanical ventilation components according to this new regulation.

Cuisines professionnelles - Soigner la détermination du débit d'air extrait Professionnal kitchen - To determine exhaust ventilation rate

The aim of ventilation for commercial kitchens is capturing fumes and odours, providing fire protection measures and insuring comfort. But the technologies concerning extraction and introduction of fresh air are not numerous.In this article, the author explains how difficult are the dimensioning of the equipment and the calculation of the airflow to extract.The author also refers to guide and regulations related to commercial kitchens.

Design analysis of single-sided natural ventilation

This study concerns single-sided natural ventilation by using a CFD model, along with analytical and empirical models. The effects of opposing buoyancy and wind forces on ventilation rates and indoor conditions were alos studied in that investigation.

Demand controlled ventilation for office cubicles - can it be profitable ?

Ventilation systems designed for a constant air volume (CAV) provide fresh air in office buildings. It means that very often huge amounts of energy can be wasted on ventilating empty offices. A simple analysis of the profitability of Demand Controlled Ventilation (DCV) has been performed on a reference office building in Norway.

Application of fuzzy control in naturally ventilated buildings for summer conditions

The aim of that study was to develop a fuzzy controller for naturally ventilated buildings. This paper describes the process of designing a supervisory control to provide thermal comfort and adequate air distribution inside a single-sided naturally ventilated test room.

Maintenance of HVAC-Systems and components, definition of cleanliness

Maintenance of air-conditioning systems is acknowledged as an important means to run HVAC-systems properly. Although several maintenance programs and standards exist, not many systems are maintained in a proper way. Most standards and programs are not concerned with the indoor environment, they are only concerned with repair and failure-response of system components. Just now, some new guidelines come out in Europe, which contains first definition of cleanliness.

The effect of external conditions on indoor air quality in new buildings

The development of indoor air quality was studied in three newly finished buildings in Helsinki, Finland during the years 2000-2002. The concentration of volatile organic compounds (VOC), formaldehyde and ammonia, for which the Finnish Classification of Indoor Climate 2000 gives target values, in indoor air as well as the air exchange rate, relative humidity and temperature were determined for the newly finished buildings and 6- 12 months after the buildings had been taken in use.