Natural ventilation and thermal comfort investigation of a hawker center in Singapore.

An investigation of the natural ventilation performance of an hawker center in Singapore is the subject of that study. Thermal comfort perceptions of the users of the center have been evaluated.The impact of four variations in the structure of the building on natural ventilation has also been explored (increasing size of passageway, openings in the roof, removal of end walls and increasing of the roof height)

Scale model study of airflow performance in a ceiling slot-ventilated enclosure : isothermal condition

The experimental investigation of airflow performance in a ceiling slot-ventilated enclosure under an isothermal condition was the aim of that study. Air-flow characteristics have been analyzed via experimental data then compared to literature theoretical expressions.
The results will be used in design guidelines of ventilation system for controlling indoor environment.

Material properties, room-climate measurements and building history - an interdisciplinary project to set the conditions of restoration and re-use for the fortress of Kufstein, Tyrol, Austria

For the restoration of the historic fortress of Kufstein, the high humidity problems encountered have required special investigations : the capillary water up-take characteristics of the wall stones and identification of the ventilation deficiencies have been studied.
Results show that a controlled ventilation system may help to reduce the problems associated with humidity and condensation.

Mineral oil residues on HVAC components : measuring methods

This paper presents a method to determine the amount of oil residues in HVAC components surfaces. That method has been validated. It appears that the oil concentration of studied HVAC components depends on the technique used for their manufacturing.

Integrated IAQ model for prediction of VOC emissions from building material

An integrated IAQ model has been developed for prediction of Volatile Organic Compounds emission rate of building material and concentration distribution within a material.Experimental data have validated the model predictions. The results of the experiment tallied with the model predictions.

Development and application of an indoor air quality audit to an air-conditioned tertiary institutional building in the tropics

This paper is the presentation of the development and application of an IAQ audit methodology applied in tertiary institutional buildings in the tropics. For that study, a staff room and a typical lecture theatre have been selected.The IAQ audit consisted in monitoring thermal comfort parameters. In parallel the staff and students have answered a questionnaire to give a subjective assessment of the indoor air quality.The IAQ results will be then used to develop an IAQ database for institutional buildings in Singapore.

Building materials VOC emissions - a systematic parametric study

This paper gives the description of a four-factor simulation design and a statistical procedure for analyzing material VOC time sensitivities with regard to the following parameter variations : VOC diffusion coefficient, VOC partition coefficient, material thickness, surface air velocity, along with their interaction effects.

Thermal comfort prediction for a new passive cooling system

This paper aims at estimating the thermal comfort in environment created by a proposed passive evaporating cooling system. The evaporative effect from water falling along guides is used to produce a reduction in the temperature of the air entering the building.

Adaptive comfort temperature model of air-conditioned building in Hong Kong

This paper deals with the results of a large-scale survey performed to develop new notions about ACT (adaptive comfort temperature) in buildings in humid sub-tropical Hong-Kong ; the aim was to determine the adaptive interface relationship between indoor comfort temperature and outdoor air temperature in order to preset the indoor air temperature as a function of the oudoor air temperature.

Indoor air quality and energy issues of refrigerant modulating air-conditioning systems in the tropics

Due to its simplicity in installation and maintenance on the one hand, and to its potential to conserve energy on the other hand, the refrigerant modulating air-conditioning system has become very popular. This paper presents the results of an IAQ energy audit of two buildings in Singapore that use that kind of system. The results are compared to those obtained from conventional air-conditioning systems.