Health in occupants of energy efficient new homes

A pilot questionnaire study was carried out on two groups: 128 occupants of new homes' (52 R-2000) on the one hand and 149 occupants of control homes on the other hand: both the groups were questionned to compare their general and respiratory health at occupancy and one year later. Symptom scores improved significantly over the year of occupancy for the occupants of energy efficient homes.

Impact of turbulence anisotropy near walls in room airflow

Re-number k-e model is the most used turbulence model in Computational fluid dynamics. But sometimes that model does not produce good results and Reynolds stress model (RSM) improves the prediction of the velocity in the jet. Measurements and observations of streamline patterns prove it.

Evidence of inadequate ventilation in portable classrooms : results of a pilot study in Los Angeles County

This paper deals with a pilot study in portable classrooms where neither adequate ventilation nor associated conditioning of indoor air for occupant comfort were provided. Concentrations of pollutants should be mitigated with an appropriate ventilation and should lead to a reduction of symptoms of "sick building syndrome"

Modeling the internal dynamics of energy and mass transfer in an imperfectly mixed ventilated airspace

This paper deals with a modeling approach that combines the classical heat and moisture balance differential equations along with the use of experimental time-series data. This approach provides an ideal form for advanced model-based control system design.

What real-world experience says about the UFAD alternative

This article aims at providing an overview of recent field experience, as reported in the literature, about underfloor air distribution systems (UFAD) as an alternative to conventional air distribution.

Duct cleaning: Do homes need it ?

This paper gives a description of the cleaning of metal ducts in small buildings, located in heating climates in the northern US states, with different cleaning techniques, their cost, and advices from different trade associations.

Implications of ASHRAE's guidance on ventilation for smoking-permitted areas

This article presents the difficulty for ASHRAE to take into account the high levels of ventilation requiries and to combine them with the demand for "guidance" encouraged by the tobacco industry and its allies.

Three approaches to replacement air delivery

This article focuses on the replacement air component for atrium smoke exhaust, including comparisons of three design approaches. The concepts are illustrated by case studies.

Sizing VAV boxes

This article sums up a detailed analysis of variable air volume (VAV) box control. Sizing criteria are provided in order to minimize the life-cycle cost in typical application.

Best practices for selecting diffusers

As the office environment is always changing new ways of looking at diffuser selection is mandatory.Changes in the office air delivery system may be due to new building codes/regulations, or to changing interior loads.New technologies allow innovative manners to treat heating and cooling needs. Some strategies may be used in retrofitting.