Exposure assessment for respirable particulates associated with household fuel in rural districts of Andhra Pradesh, India

This study quantified the daily average concentrations of respirable particulates in rural homes from three Indian districts. Thanks to this data a model is being developed to predict quantitative categories of population exposure based on survey information on housing and fuel characteristics. A better estimation of health risks will be possible.

Personal, indoor and outdoor VOC exposures in a probability sample of children

This paper reports the distribution of VOC exposures, and explores the statistical associations between concentrations and common sources and modifiers of exposure, and examines the associations between personal, indoor, and outdoor exposure levels in children.

Building ventilation and pressurization as a security tool

This paper discusses how ventilation and air distribution can have a positive or negative impact on chemical, biological and radiological agents entering buildings, on their movement within the buildings and on their removal. It also points out the key role played by the envelope airtightness of the building and its pressurization as a security tool.

Displacement ventilation

Advantages and drawbacks of a Displacement Ventilation system are presented in this paper, in comparison with the traditional "mixing" ventilation cooling systems.

Dezentrale Lüftungsanlagen im praktischen Einsatz Decentralized ventilation systems in practice

The first part of this article insists on the importance of a good ventilation system (polluted air exhaust, humidity, filtration, VOCs exhaust). The second part deals with a test house, equipped with either decentralized or centralized ventilation system. CO2 and ventilation rate measurements being compared, the validation of a model for the determination of the indoor CO2 concentration levels in one room of the house has been made.

La désinfection des réseaux aérauliques Disinfection of air-handling ducts

A kind of protocol for the desinfection of air-handling ducts is presented in this paper with its different steps : relationship with the customer, available techniques, prerequisites for the desinfection, choice of the products and the desinfection itself.
The limits of the system are presented too along with possibilities to develop.

Moyens et méthodes pour l'hygiénisation des réseaux Means and methods for the cleaning of air-handling ducts

The search for top quality is the requirement of the professionals of "hygienisation". A description of desinfection with its methodology applied to ducts is presented : dust removal, cleaning of the surfaces before their disinfection.

Dedicated outdoor air systems : air diffusion performance

Has the DOAS the ability to provide sufficient air movement to meet comfort requirements ? The test results from a DOAS delivering the minimum ventilation air via overhead high induction diffusers are presented in this paper.

Some schools at risk for poor IAQ

In this paper, the author presents what could be done to improve the poor indoor air quality in some schools :- A demand for accountability from school systems about maintenance procedures such as roof-leak repair, classroom ventilation and air-conditioning, presence and care of carpeting etc.- A promotion of a responsible and adequate funding for the maintenance of public facilities- The most important activity is a good, basic, responsive and adequately funded building maintenance.

A better way to predict comfort

Standard 55-2004, on thermal Environmental Conditions for Human Occupancy was recently published and approved by ASHRAE and ANSI. This article gives an overview of the key features and limits of applicability of that standard.

Pages