A successful Indoor Air Quality (IAQ) surveillance plan is essential for healthy and safe workplaces;yet it is costly to sample all air pollutants of the entire community. In Hong Kong, a voluntary IAQcertification scheme for workplaces proposes the acceptable concentration levels of nine commonindoor air pollutants, namely carbon dioxide (CO2), carbon monoxide (CO), respirable suspendedparticulates (RSP), nitrogen dioxide (NO2), ozone (O3), formaldehyde (HCHO), total volatile organiccompounds (TVOC), radon (Rn) and airborne bacteria count (ABC).
By natural ventilation, the air rate varies randomly. Therefore, it is difficult to evaluate the naturalventilation performance due to insufficient measured data. In the present work a complex office buildingwas taken as a study object for the experimental investigation. A measurement technology isdeveloped in this work for the assessment of the natural ventilation performance in the building.
The distribution of indoor airflow velocity by cross ventilation is influenced by the regional climateconditions, and the location as well as the shape of the building. In this study, CVDHI of 25 cases tochange the number and position of openings at 842 cities in Japan are calculated for the simple housemodel. The results indicate that CVDHI increases relatively in every case from the south to the north ofJapan.
This study aims to understand chemical air pollution and its influence on students and staff in auniversity building that had been under renovation for 2 years. Occupants had to move into their newrooms immediately after the renovation work was completed and so could have been exposed tochemical pollutants emitted from architectural materials.We conducted chamber testing to obtain chemical emission rates from interior use materials; whichwere the ones used for the actual work in the university building.
Much of the analysis of the potential to save energy and reduce emissions of greenhouse gases in thebuildings sector has focused on the energy savings that can be achieved through incrementalimprovements in the efficiency of individual energy-using devices (motors, fans, pumps, boilers,chillers) but without changing the way in which they are put together as systems. However, muchlarger savings are possible through changes in building systems, and further, these savings can beachieved at much smaller incremental investment cost and sometimes at lower first cost.
In 2002, the indoor environment and occupant health of approximately 800 residential buildings wereinvestigated by a questionnaire. As a result, the actual conditions of the indoor thermal environmentand the indoor air quality have been clarified, and several problems related to dampness in buildings,have been grasped. This report focuses on child health problems related to the indoor environment,especially dampness.
In this study, five different types of smoking spaces and non-smoking spaces were investigated in orderto discuss about tobacco odor leakage from smoking area. VVOCs, VOCs and aledehydes wereanalyzed for characterization of odor. Additionally, the isolation result has been identified bydetermining ETS markers (nicotine and 3-ethenylpridine) based on ISO1845.Determined compounds were quantified and categorized into 13 groups, concentration between thesmoking space and non-smoking space was compared. In the most case, the concentration innon-smoking space was lower than smoking space.
Air Quality at the height of skyscraper has not almost been cleared yet. Upper part of dwellings of tallbuildings at down town might intake inadequate outdoor air.
The purpose of this investigation is to know the long term characteristics of VOC concentrations inhouses built before the building code in 2003 and to know the need of the countermeasures in thehouses were already built for example the improvement of the living habit, ventilation and buildingmaterials. The concentrations of VOCs were measured in these houses from 2000 to 2005. The resultsshowed that the concentration of formaldehyde decreased in the first year. After that the decline of theconcentration became invisible and the concentration changed only with the temperature.
Air conditioning in offices has become current practice in North Western Europe. Main reasons are thehigh internal loads and solar gains. That move away from the heated, naturally ventilated cellularoffice increased comfort complaints.Two cases are presented, confronting enquiry results with measurements. In both, the enquiries gavea number of dissatisfied at the noted mean vote much higher than the standard PMV/PPD curvesuggests. Measurements in turn showed that only in one of the two case complaints could beexpected.