A study of a control strategy utilizing outdoor air to reduce the wintertime carbon dioxide levels in a typical Taiwanese bedroom.

A C02 concentration of more than 1000 ppm has been monitored in Taiwanese bedrooms during sleeping hours in the wintertime. The high indoor C02 levels were caused by poor ventilation due to insufficient ventilation rates. This study sought to reduce the wintertime C02 concentration level in a typical Taiwanese bedroom with less outdoor air to maintain thermal comfort. C02 was used as an indicator to assess whether an adequate ventilation rate has been obtained to dilute or remove harmful pollutants.

Airtightness construction trends.

mechanical ventilation is needed to avoid indoor air quality problems. Many new conventional houses have low natural air change rates ...... and are tight enough to require mechanical ventilation, but most have none.

The ventilation rate of 344 Oslo residences.

The ventilation in Norwegian residences was studied with respect to the effect of new standards, construction techniques adopted, and energy conservation measures implemented  This was compared to residential ventilation performance in other countries with a similar climate. The effective total air change rate (h-1) in 344 residences was measured with a passive tracer gas method known as the perfluorocarbon tracer gas method (PFT-method). The measurements were performed over a 14-day integrated sampling period.

Evaluation of site-specific risk assessment for contaminated lands.

This report provides the results of a two-phased study conducted for the Canada Mortgage and Housing Corporation (CMHC) to examine the practices and variability amongst practitioners of contaminated sites risk assessment in Canada. Phase I consisted of a survey of practitioners in the private and regulatory sectors. The intent of the private sector survey was to characterize the capabilities and experience of private firms engaged in human health risk assessment across Canada.