Submitted by Maria.Kapsalaki on Tue, 03/22/2016 - 09:25
The long term exposure to fine particulate matter with a diameter of ≤2.5 μm (PM2.5) is linked to numerous health problems, including chronic respiratory and cardiovascular diseases, and cancer. In dwellings, a primary emission source of PM2.5 is cooking, an activity conducted several times per day in most households. People spend over 90% of their time indoors and more time in their homes than any other type of building. Therefore, they are at risk of exposure to elevated levels of PM2.5 emitted by cooking if these particles are not removed at source.
Submitted by Maria.Kapsalaki on Tue, 03/22/2016 - 09:19
To study the impact of the filtration efficiency level on the particle concentration in a rural school equipped with a balanced ventilation system with heat recovery, measurements of indoor and outdoor particle concentrations have been carried out by using three different efficiency filters. The tested filters are respectively classed G4, F7 and F9 according to NF EN 779 (2012).
Submitted by Maria.Kapsalaki on Tue, 03/22/2016 - 09:18
Radon gas is a pathological agent confirmed by World Health Organization in terms of increasing the risk of lung cancer generation when it is inhaled by human in high concentration. This gas comes from soils with uranium content (i.e. granite terrain) and penetrates through the building envelope, such, as floors or basement walls. Its accumulation in indoor spaces increases the radon concentration level, constituting a health problem for occupants. This can be handled by rehabilitation actions in buildings that reduce indoor concentration to acceptable levels.
Submitted by Maria.Kapsalaki on Tue, 03/22/2016 - 09:16
The aim of this paper is to show the effects of variable ventilation rates on the demand of energy and air quality in dwellings, and how airtightness and wind affect this relation. It is interesting to estimate the relation between the air ventilation rate and airtightness of dwellings which makes the dwelling to be under-pressure in order to avoid infiltrations.
Submitted by Maria.Kapsalaki on Tue, 03/22/2016 - 09:14
Within this paper, an evaluation of Indoor Air Quality in residential buildings, and the experience after a building retrofit is shown. One residential building in a Madrid social housing neighbourhood serves as case study and base for the monitoring.
Submitted by Maria.Kapsalaki on Tue, 03/22/2016 - 09:11
The purpose of this paper is to enhance the importance of ventilation regarding energy use and stablishing methods in order to obtain as much data as possible about the behavior patterns of ventilation and infiltration in buildings.
Submitted by Maria.Kapsalaki on Mon, 03/21/2016 - 11:56
Comfort and energy saving are two important concepts treated in current buildings in order to maintain a good air quality reducing the energy consumption. According to International Energy Agency (IEA) buildings represent 32% of total final energy consumption, and the need for reduction of CO2 emission leads to pay attention to the energy demand in buildings. On the other hand maintaining a good-quality environment helps to improve the productivity and effectiveness of workers.
Submitted by Maria.Kapsalaki on Mon, 03/21/2016 - 11:42
The control of heat losses, inwards/out, in nearly zero energy buildings is of high importance. The transmission losses through the building envelope are easily reduced using larger amounts of insulation. Calculation of the impact of this action on the total energy demand of the building, is quite standard. It’s however much more difficult to determine the efficiency of actions to increase the airtightness of the building and the influence of the ventilation system.
Submitted by Maria.Kapsalaki on Mon, 03/21/2016 - 11:04
As an alternative to adopting active architectural systems (mechanical systems) and taking advantage of the resources provided by nature, natural ventilation contributes interesting solutions to control the thermal balance and the air quality, and it is applicable in a variety of climate zones. Natural ventilation also solves some of the more common problems of mechanical systems, such as the noise factor and installation and maintenance costs.
Submitted by Maria.Kapsalaki on Mon, 03/21/2016 - 11:01
Ventilation plan for smoking room must deal with pollutants since they affect the air quality of adjacent rooms. Although ventilation plan typically maintains a negative room pressure to remedy this problem, the transport of indoor air pollutants between rooms is affected by moving objects, such as human movement and door opening. The purposes of this study were to evaluate the effects of moving objects on the rate of transport of indoor air pollutants and to propose a method of controlling contamination for smoking room.