Application of a new type of air and vapour retarder in a self drying dloped roof with a cathedral ceiling.

In cool and cold climates, sloped roofs with cathedral ceilings are quite sensitive to moisture damages caused by built-in moisture and prolonged concealed condensation of water vapor produced inside. Conventional solutions are to leave a cavity between the thermal insulation and the sheathing and vent it with outside air and/or to include a vapor barrier below the insulation layer. An alternative, however, is the self-drying roof. This concept was evaluated experimentally.