Indoor air pollution due to emissions from unvented gas-fired space heaters.

Operation of an unvented combustion appliance indoors can elevate pollutant concentrations. Under laboratory conditions, oxygen consumption rates and pollutant emission rates of CO, CO2, NO, NO2, HCHO and submicron suspended particles emitted

Measurements of indoor air quality and comparison with ambient air. A study on 15 homes in Northern Italy.

A survey was carried out on 15 homes in Northern Italy to evaluate the occurrence of 35 selected volatile organic compounds and of total volatile organics in indoor air and in ambient (outdoor) air. Respirable suspended particulates and venti

Air infiltration and indoor air quality - a critical review.

Covers the factors affecting air infiltration and indoor air quality, the utility of existing air infiltration models, and the ideal and practical requirements of a relevant indoor air quality model that could be used as a tool for management of atmosphere in tightly enclosed residential spaces.

Indoor air pollution in the Netherlands.

Reports results of studies of concentrations of carbon monoxide, nitrogen dioxide, respirable suspended particulate matter and volatile hydrocarbons in houses in the Netherlands. Carbon monoxide and nitrogen dioxide were studied in about 300 homes in Arnhem and Enschede in October-December 1980. Respirable suspended particulate matter, nitrogen dioxide and volatile hydrocarbons were measured in 175 houses in Ede in winter 1981-82. Indoor air pollution was often much higher than the common outdoor levels. In several houses existing or proposed standards for ambient air were exceeded.

Indoor carbon monoxide and nitrogen dioxide pollution in the Netherlands.

Describes the influence of gas geisers on carbon monoxide and nitrogen dioxide production in 254 houses in the Netherlands. It was shown that burner type and maintenance system were the main factors influencing the carbon monoxide levels in the flue gases. The nitrogen dioxide concentration in the kitchen was greatly influenced by the presence of a flue for the geiser and by use of a cooker hood. Associations were also found with type of space heating, use of shower and socioeconomic status of the occupants.

Indoor NOx pollution.

Discusses sources of nitrogen dioxide in indoor air in houses in the Netherlands. Measurements were made in a random sample of about 300 houses with a geiser in Enschede and Arnhem. A second sample of 326 houses in Ede were measured a year later. The Dutch outdoor standard for concentrations of nitrogen dioxide was regularly exceeded indoors.

Indoor nitrogen dioxide pollution and respiratory symptoms of school children.

The influence of indoor nitrogen dioxide exposure on respiratory symptoms of school children was investigated in a case-control study. The election method used was useful in obtaining symptomatic children, but insufficient indefining cases and controls without additional information. No relationship between indoor NO2 and respiratory symptoms was found. Bias may have been present, especially because of the high mobility of the study population. Attempts to estimate historical exposure were inaccurate.

The relationship between indoor nitrogen dioxide concentration levels and personal exposure: a pilot study.

A small, personal monitoring study was performed in a subpopulation (14 families) of a case-control study on the relationship between indoor nitrogen dioxide exposure and respiratory diseases of school children. 

Indoor NO2 pollution and personal exposure to NO2 in two areas with different outdoor NO2 pollution.

Indoor NO2 concentrations were measured in the kitchen, the living room and bedroom of 612 houses in two different areas in the Netherlands. In asub-sample, personal exposure of the housewives to NO2 was measured. NO2concentrations indoors depended on the presence or absence of (un)vented gas appliances. Personal NO2 exposure was only different between the two areas in the group with the lowest indoor concentrations. It was concluded that with respect to NO2 exposure it is impossible to categorize groups without accounting for gas appliances inside the house.

Pollution concentrations in buildings.

Pollutants in a substantial number of buildings have now been investigated by public and private agencies. The archive of data on indoor pollutant levels observed in office buildings under conditions of normal operation and occupancy are reviewed using a computer based Building Performance Database. Representative values of 153 pollutants as well as detailed frequency distributions of commonly measured pollutants and of temperature and humidity are presented.