Distribution of Particulate Matter Concentration and Temperature Stratification Examined by Zonal Model and Experimental Measurements in Room with A Novel Portable Displacement Ventilation Cooling Unit

This study introduces a novel conceptual design of a mobile DV cooling unit that is aimed to support the ventilation and reinforce the thermal stratification in DV rooms. Supplying filtered chilled air from at low height, the portable DV unit (PDV unit) functions as if it is a typical DV diffuser. Moreover, the PDV unit employs heat exhausted from the heat pump to reinforce the temperature gradient by injecting the hot air flow in the upper zone of the room. Utilizing the exhaust air makes the PDV unit entirely ductless which adds to its flexibility placed in to balance the airflow.

Vertical Distribution of Temperature and Contaminant Concentration in a Room with Impinging Jet Ventilation System

The impinging jet ventilation system (hereinafter referred to as IJV) has been proposed as a new air conditioning ventilation system. Properties of indoor environment with this system using impinging jet are complicated. The present paper reports fundamental properties of indoor air with distributed interior heat generation load assuming an office. The experiment was conducted in the climate chamber of which floor area was 27.0 m2, and basic properties of temperature and CO2 distributions were investigated.

A RSM model for the prediction of heat and mass transfer in a ventilated room

A full-scale test room is used to investigate experimentally and numerically the velocity and temperature fields in the case of a mechanical ventilation. Detailed fields are measured for three cases of ventilation air temperature: an isothermal case, a hot case and a cold case. The experimental data are used to test two turbulence models: a first order k-ε turbulence model and a second order RSM turbulence model. The RSM model predicts the temperature and velocity fields better than the k-ε turbulence model.

Study of the ventilation efficiency under some typical air flow conditions in a mechanically ventilated room.

The present study deals with indoor air quality and is mainly based on an experimental work. The experimental set up is a full scale test cell with a ventilation system which comprises a fixed air supply and a mobile extract. A source of pollutant continuously supplies tracer gas at the centre of the cell. We carried out 12 tests under steady state and with various conditions. The test parameters were the exhaust location, the fresh air now rate and the supply air temperature.