13-14 September 2017, Conference, Nottingham, 38th AIVC conference

The 38th AIVC conference "Ventilating healthy low-energy buildings" was held on 13 & 14 September 2017 in Nottingham together with the 6th TightVent conference and the 4th venticool conference. There were 185 participants.

The conference consisted of 3 parallel tracks largely devoted to:

English

CIBSE’s COVID-19 Ventilation Guidance

CIBSE initially published COVID-19 Ventilation guidance on 9th May, followed by Version 2 on 12th May and Version 3 on 15th July, in response to the CIBSE position, taken in April, that there was the potential for airborne aerosol transmission of SARS-CoV-2. Version 4 was published on October 23rd.

 

This guidance adopts a precautionary approach with the objective of ventilating spaces as much as reasonably possible with outside air as one measure to reduce transmission risk.

 

English

Refined assessment and comparison of airtightness measurement of indoor chambers using the blower door and Pulse methods

Previous studies have compared the airtightness measurement of test enclosures utilising both the novel Pulse technique and the conventional blower door method.  Discrepancies between results of the two test methods were observed and it was concluded that differences either caused by wind or blower door installation integrity would have had an impact upon the results.

Evaluation of indoor pressure distributions in a detached house using the Pulse airtightness measurement technique

Building airtightness is a critical aspect for energy-efficient buildings as energy performance of a building can be reduced significantly by poor airtightness. The Pulse technique has been regarded as a promising technology, which measures the building airtightness at a low pressure of 4Pa by rapidly releasing a 1.5-second pulse of air from a pressurised vessel into the test building and thereby creating an instant pressure rise that quickly reaches a “quasi-steady” condition. However, questions have often been asked on the test viability due to the nature of the test.

Insights into the impact of wind on the Pulse airtightness test in a UK dwelling

Requirements for measuring the building airtightness have been proposed and included by many countries for national regulations or energy-efficient programs to address the negative effect of poor airtightness on building energy performance, durability and indoor environment. The methods for measuring building airtightness have continuously improved and evolved over a number of years.

Lessons learned from design and operation of ventilation systems in low-energy dwellings in the UK

This presentation will cover the key lessons learned from post-occupancy evaluation of the ventilation strategies in several new-build dwellings in the UK. Two ventilation strategies often used for new dwellings in the UK are mechanical extract ventilation (MEV) and whole-house balanced mechanical ventilation with heat recovery (MVHR). Few examples of the design and operation of these systems will be presented identifying the best practice and improvement opportunities for mechanical ventilation systems that are increasingly used in airtight low-energy dwellings. 

The AIVC of the 20th Century

This report reviews the activities of the AIVC during its first twenty years of operation. It identifies key projects and addresses them in the context of research activities and associated issues of the time. Early issues included the need for energy conservation and reducing air infiltration loss. Much work concentrated on assessing the performance of numerical models and acquiring input and validation measurement data. Towards the end of the period attention focused towards energy efficient ventilation systems for good indoor air quality and comfort.

Numerical Modelling of Large Air-Conditioned Space: Comparison of Two Ventilation Systems

This paper presents a comparative study based on CFD simulation between the performance of Impinging Jet Ventilation (IJV) and Mixing Ventilation (MV) systems in providing indoor air quality and thermal comfort for a mechanically ventilated occupied large open plan office (floor-to-ceiling height > 5m). Large spaces differ from spaces with standard heights because of the significant upward stratification.

Comparison between infiltration rate predictions using the divide-by-20 rule of thumb and real measurements

Across different territories there are various normative models for assessing energy demand of domestic dwellings, which use simplified approaches to account for the heat loss due to the air infiltration of a building.  For instance, the United Kingdom uses a dwelling energy model, known as the Standard Assessment Procedure (SAP), and this utilises a process where the measured air permeability value (q50), is simply divided by 20 to provide an infiltration rate (subsequent modification factors are then used for factors such as sheltering etc.).

On the experimental validation of the infiltration model DOMVENT3D

Buildings represent approximately 40% of global energy demand and heat loss induced by uncontrolled air leakage through the building fabric can represent up to one third of the heating load in a building. This leakage of air at ambient pressure levels, is known as air infiltration and can be measured by tracer gas means, however, the method is disruptive and invasive. Air infiltration models are a non-disruptive way to calculate predictive values for air infiltration in buildings.