Dynamic performance of displacement ventilation in a lecture hall

An accurate temperature gradient calculation is essential for displacement ventilation (DV) system design, since it directly relates to the calculation of the required supply air flow rate. Inaccurate temperature prediction can cause the poor thermal comfort and w sizing of the ventilation and cooling systems.

The flow interaction of air distribution with thermal plumes and the effect on the air velocity fluctuation under increased heat load conditions

Flow interaction between thermal plumes and vertical air distribution and the resulting airflow structures were investigated under increasing heat load conditions. The main objective was to investigate the large-scale flow patterns, airflow fluctuation and frequency of the flow field. The flow interaction between thermal plumes and ventilation provides random flow motion and vortical structures that further effect the airflow characteristics such as velocity and temperature fields, turbulence intensity and frequency of the fluctuations.

The effect of adjustable cooling jet on thermal comfort and perception in warm office environment – a laboratory study

The aim was to study how the cooling jet from the ceiling, with individual control over the airflow, is perceived and how it affects the thermal comfort in warm office environment. 32 undergraduate university students participated in the experiment. Two thermal conditions were tested: (1) no cooling jet and (2) adjustable cooling jet from the ceiling. Subjects were able to use a controller with seven different settings to adjust the airflow coming from the nozzles so that the target velocity varied from 0.3 m/s to 1.5 m/s. The cooling jet was directed into the upper body.

The Cleanliness Classification of Air-handling Components- A success Story in Finland

INTRODUCTION: The Finnish Society of Indoor Air Quality and Climate (FiSIAQ) introduced over twenty years ago in 1995 a Classification of Indoor Climate, Construction Cleanliness, and Finishing Materials and the third edition will be published autumn in the year 2017. Based on the criteria set in the classifications, The Building Information Foundation RTS sr started the M1-labelling of air handling components in 1999. Name of the classification is Cleanliness Classification of Air Handling Components.

RoomVent & Ventilation 2018

RoomVent and Ventilation joint Conferences will provide an overview of the latest research findings on ventilation in both industrial and non-industrial premises.

English

Aalto University Finland

25-28 September 1989, Conference, Espoo - 10th AIVC Conference

The 10th AIVC Conference - Progress and trends in air infiltration and ventilation research, was held in Espoo, Finland, 25-28 September 1989. Contains 52 papers.

English

Halton