Submitted by Maria.Kapsalaki on Thu, 02/06/2020 - 15:20
An accurate temperature gradient calculation is essential for displacement ventilation (DV) system design, since it directly relates to the calculation of the required supply air flow rate. Inaccurate temperature prediction can cause the poor thermal comfort and w sizing of the ventilation and cooling systems.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 15:07
Flow interaction between thermal plumes and vertical air distribution and the resulting airflow structures were investigated under increasing heat load conditions. The main objective was to investigate the large-scale flow patterns, airflow fluctuation and frequency of the flow field. The flow interaction between thermal plumes and ventilation provides random flow motion and vortical structures that further effect the airflow characteristics such as velocity and temperature fields, turbulence intensity and frequency of the fluctuations.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 11:49
The aim was to study how the cooling jet from the ceiling, with individual control over the airflow, is perceived and how it affects the thermal comfort in warm office environment. 32 undergraduate university students participated in the experiment. Two thermal conditions were tested: (1) no cooling jet and (2) adjustable cooling jet from the ceiling. Subjects were able to use a controller with seven different settings to adjust the airflow coming from the nozzles so that the target velocity varied from 0.3 m/s to 1.5 m/s. The cooling jet was directed into the upper body.
Submitted by Maria.Kapsalaki on Thu, 11/23/2017 - 10:56
INTRODUCTION: The Finnish Society of Indoor Air Quality and Climate (FiSIAQ) introduced over twenty years ago in 1995 a Classification of Indoor Climate, Construction Cleanliness, and Finishing Materials and the third edition will be published autumn in the year 2017. Based on the criteria set in the classifications, The Building Information Foundation RTS sr started the M1-labelling of air handling components in 1999. Name of the classification is Cleanliness Classification of Air Handling Components.
Submitted by Maria.Kapsalaki on Tue, 02/14/2017 - 09:16
RoomVent and Ventilation joint Conferences will provide an overview of the latest research findings on ventilation in both industrial and non-industrial premises.
Submitted by Maria.Kapsalaki on Mon, 06/30/2014 - 14:49
The 10th AIVC Conference - Progress and trends in air infiltration and ventilation research, was held in Espoo, Finland, 25-28 September 1989. Contains 52 papers.