A Study of Design principle and Technology performance applied in Passive House

Recently, the role of the architecture which is corresponding to climate change and saving energy has been important. This study drew factors about design principle, technology performance on passive house, focusing on apartment and multi-family house cases in Europe. The dwelling type of Korea and climate, however, are different from the European styles, and therefore it is necessary to develop energy efficient design, technology and details that is applicable to Korea's apartment.

Indoor Thermal Environment and Vertical Temperature Gradient in Large Workshop of School without air-conditioning

The purpose of this study is to figure out the characteristics of thermal environment in a workshop at school in Japan and to propose the improvement method of the thermal environment without air-conditioning systems. In this paper, measurement results of thermal environment in the workshop and calculation results of vertical temperature gradient are shown. In the measurement results, indoor air temperature became very high in summer. Solar radiation was the main factor raising the temperature of PC roof, and large vertical temperature gradient was formed.

School Eco-Renovation Method for Improvement of Thermal Environment in Large Workshop of High School without Air-Conditioning System

In recent years school buildings, containing the workshop in high school, are old in Japan. Therefore most of them need renovating. Any air-conditioning systems are not often installed in the workshops. Workshops without air-conditioning systems often have bad indoor thermal environments. Since bad thermal environment is exhausting and likely to cause some accidents, eco-renovation method for improvement of thermal environment is required. In this paper, various kinds of eco-renovation methods are examined by CFD simulation.

Evaluation on the Availability of Treated Sewage Water as an Unused Energy Source in a Super High-rise Complex Building

Because the super high-rise complex building would be designed vertically with a mixed-use space, a large amount of unpurified domestic sewage could be discharged continuously outside the building site. The waste heat from the sewage water can be used for low temperature heating and high temperature cooling sources for HVAC system such as radiant heating and cooling system, and domestic hot water services. This study aims to evaluate the availability of treated sewage water as an unused energy source in a super high-rise complex building.

Field Survey on Indoor Thermal Environment in Small to Medium Sized Building with Packaged Air Conditioners

Recently, a lot of multiple packaged unit system is adopted in small to medium sized buildings in Japan. This system enables to control each packaged air conditioner (PAC) individually because multiple packaged units are placed decentrally. However, it is not clarified sufficiently how indoor environment is formed when PAC is working. This paper shows the measurement results of indoor thermal environment in a medium sized building with PAC in all season for the purpose of clarifying the current status of indoor environment and its issue.

Energy-saving Effect of Thermal Energy Storage Using Introduced Outdoor Air

Recently, buildings with thermal energy storage system have increased because of its economic advantage. In thermal energy storage system using introduced outdoor air, building masses are used as thermal storage media and cooled by outdoor air introduced by a mechanical fan in night-time. In spring and autumn, the cooled building masses can work to reduce cooling load in day-time. In this study, the stored heat was calculated by using simple heat transfer models for various building masses, and the energy performance of this system was evaluated quantitatively by system simulation.

A Study on the Hybrid Air-conditioning system Coupled with Radiant Floor Cooling and Ventilation System

In this study, the concept of the Hybrid air-conditioning system utilizing convection and radiation heat exchange will be suggested. In this paper, the heat removal characteristics of Hybrid air-conditioning system will be described by theoretical review and experimental methods. Also the ratio of cooling load removed by Hybrid air-conditioning system could be divided as radiation and convection heat exchanges. The methods could be used to system design of Hybrid air-conditioning system.

Thermostat/Hygrometer vs ANN-Based Predictive/Adaptive Environmental Control Strategies

This study tested the feasibility of employing artificial neural network (ANN)-based predictive and adaptive control logics to improve thermal comfort and energy efficiency through a decrease in over- and under-shooting of control variables. Three control logics were developed: (1) conventional temperature/humidity control logic, (2) ANN-based temperature/humidity control logic, and (3) ANN-based Predicted Mean Vote (PMV) control logic.

Investigation of the Usage of Ground Source Heat Pump System on Wall Heating

Wall heating systems are more preferable heating systems than other conventional systems due to their low temperature operating ranges. These systems are equipped with heating serpentines or panels where the water is circulated and the serpentines are mounted on the walls of rooms. Ground source heat pump systems are todays one of the useful renewable energy based heating systems.

Simple error reduction in tracer-gas field-measurements of air handling units