Estimation of excessive HVAC energy consumption due to faulty VAV units

The present paper investigates, both experimentally and by simulation, the influence of faulty VAV units that do not affect the zone temperature on total energy consumption of a VAV system. In an experimental room, the respective total energy consumptions of both normal operation and faulty operation were measured. The results indicate that a faulty unit affects other normal units, causing an energy waste of approximately 20-50%.

Energy efficiency and thermal comfort analysis using the powerdomus hygrothermal simulation tool

The building simulation tool Domus has been recently renamed as PowerDomus for whole-building hygrothermal and energy simulation. Enhancements have been accomplished by improving the features for input and output data applied to multizone buildings, by adding HVAC systems and plants, by adding attics among other Graphical User Interface (GUI) features and by improving the numerical algorithms for calculating Sun angles, shading projections and moisture prediction through composite walls using moisture content as driving potential.

Energy performance of buildings evaluated with multivariate analysis

Numerous problems can occur for an investigator of larger datasets, e.g. how to handle dimensionality, many variables and few observations, few variables and many observations, correlations, missing data, noise and to extract information from all data simultaneously. Multivariate analysis (MVA) is an established method for dealing with such problems. In this work, we introduce a methodology based on MVA, which was developed to model the building energy performance from the perspective of the property holder.

Energy and thermal analysis of glazed office buildings using a dynamic energy simulation tool

Highly glazed buildings are often considered to be airy, light and transparent with more access to daylight than traditional buildings, but their energy efficiency is often questioned. This article deals with energy and indoor climate simulations of single skin office buildings in Sweden using a dynamic energy simulation tool. Different building alternatives were studied with 30%, 60% and 100% window area.

Energy declaration of buildings and building details

The paper deals with two construction details and discusses the opportunities and limits of their computer aided building simulation. Both details occur in the area of building renovation and modernization. The first is a 3-D joint of a partially protruding roof terrace with surrounding walls and a pitched roof, and the second is a fragment of the thick, rough, non-plastered stone wall of a building monument with adjacent additionally insulated walls and roof.

Energy consumption optimization of a small spanish airport

To have a proper energy management in buildings, it is necessary to evaluate its HVAC system. To properly compare operating strategies and solve possible problems, one needs to reproduce the building and its HVAC system behavior under real life conditions (building materials, cooling, heating and ventilation demands, meteorological conditions, etc.).

Energy and financial performance of micro-chp in connection with high-performance buildings

This paper deals with the issue of using micro- Combined Heating and Power plants (mCHP) in high-performance houses in terms of energy conservation and cost savings. On the one hand, since mCHP systems have only a modest electrical conversion efficiency, effective exploitation of the thermal output is critical to achieving high levels of energy efficiency. On the other hand, modern high performance residential buildings display a heat-topower load ratio that does not match well with the heat-to-power supply ratio of mCHP.

Energuide for houses database – an innovative approach to track residential energy evaluations and measure benefits

The EnerGuide for Houses (EGH) database is a management information tool and central depository for tracking residential energy evaluations and measuring benefits from the energy evaluations delivered across Canada. The EGH database is a comprehensive computer-based system developed by Natural Resources Canada (NRCan) for the management of its energy efficiency oriented programs. Energy advisors perform detailed house energy efficiency evaluations and use the energy analysis software to recommend energy efficiency measures to homeowners.

Encapsulation of validation tests in the esp-r simulation program

It is well recognised that validation of dynamic building simulation programs is a long-term complex task. There have been many large national and international efforts that have led to a well-established validation methodology comprising analytical, inter-program comparison and empirical validation components, and a significant number of tests have been developed.

Elements of a simulation-assisted daylight-responsive illumination systems control in buildings

This paper presents a simulation-assisted daylightresponsive illumination control system. The controller application in this system can dynamically adjust the position of window blinds and the status of the room luminaires to achieve user-specified performance levels. In its main mode of operation, the control application considers in regular time intervals a set of alternative combinations of the states of control devices (e.g. position of window blinds, dimming levels of luminaires) for an immediate next time step.