Potential for natural ventilation in urban context : an assessment method

The natural ventilation potential (NVP) is the possibility, or probability, to ensure anacceptable indoor air quality by natural ventilation only. A passive cooling potential (PCP)can also be defined, as the possibility to ensure an acceptable indoor thermal comfort usingnatural ventilation.

Guidance and tools for chilled ceilings combined with a wet cooling tower

The combination of an open wet cooling tower with chilled ceilings is a CFC free, cheap and low energy cooling solution. The efficiency of this alternative to mechanical cooling is very dependent on climate. There is a need for specific tools to help designers to size the system and to estimate its energy and water consumption. A building simulation tool, called ConsoClim, has been used to predict the performance of this system for different French climatic locations, thermal inertia, internal loads and solar gains.

Field measurement of the airtightness and delivery effectiveness of HVAC duct systems.

This paper presents the results of a field study on five HVAC duct systems in France. The principal objectives of this work were a) to evaluate the extent of duct leakage in those systems; b) to compare design and actual fan flow rates; c) to evaluate the thermal energy losses in the air ducts. The ductwork airtightness, measured by fan pressurisation method, was found to be in general well above the leakiest EUROVENT 2/2 class (class A), yielding unacceptable uncontrolled airflows. Fan airflow rates were measured with the constant injection tracer gas method.

Pressure Drop in and Noise Radiation from Rectangular and Round Ducts - Literature Survey -

In this paper, a literature survey on rectangular and round ventilation ducts is presented. The comparison is based on two important aspects: pressure drop and noise radiation. The pressure losses in the ductwork should be kept as low as possible without jeopardizing proper control of the flow rates in the system. Pressure loss through a rectangular duct is significant higher than a volumetrically equal round one. The higher the aspect ratio, the higher-pressure loss in the rectangular system.

A synergy-facade in a paslink test cell

This paper describes a modular facade system, which supplies the room behind with the necessary amounts of heat, light and fresh air. Aims of the development of this facade were both to achieve a high degree of comfort for the users and to save energy in comparison to a conventional facade. The experimental investigations to assess and to optimize the facade system were performed in a PASLINK test cell. These test cells allow measurements of the thermal and solar performance of facade elements in original dimensions and under natural climate conditions.

Assessing the influence of the urban context on building energy demand.

An energy balance over an urban area and over a rural one, reveals that the first case is always more complex than the last one. The urban context is able to change all the energy transferences mainly due to its own layout. Thus, analysing all the energy transferences one by one, we can find how they affect in a different way depending on the surroundings, among other influences.

Thermal comfort in Algeria - Preliminary results of a field study

A field survey on thermal comfort in Algeria has never been previously attempted, and for this reason the present study was conducted. The present paper will present a field study of thermal comfort in Algeria. A thermal comfort survey has been held among 160 persons in 4 towns of Algeria representing three different climatic regions. The survey has been carried out in two different types of buildings: Domestic buildings and Office buildings. Subjective data were collected from 160 people by the use of questionnaires.

Radiant ceiling heating and local thermal discomfort

In the introduction of the paper are reasons presented, which cause local thermal discomfort. Currently the reasons of asymmetric thermal radiation are not clearly explained. Therefore I oriented my experimetal laboratory measurements, which were carried out in a special microclimatic laboratory on radiant ceiling heating. A special laboratory model of heating of interior was created. The measurements were performed with the help of a thermal mannequin that was used to measure the asymmetric radiation (that is asymmetry of perceived temperature).

A survey on auditory, visual, thermal comfort at a library

A research project is designed to evaluate different aspects affecting human comfort in an architectural space. One of the basic parts of the research project is the evaluation of the auditory, visual and thermal comfort. A university library in Istanbul is selected as the subject of the research. The library building, which has unusual settlement and design peculiarities, is an interesting case from acoustical view point as well, because of the closeness to a heavy traffic road and architectural properties.

How demanding is global approach to indoor environmental quality assessment ?

The indoor environmental quality of a building is intended as the thermal, visual, acoustic and indoor air quality performances as a whole, which provide health and comfort for occupants. In architecture, global approach to environmental quality design is necessary. High levels of quality are needed for each aspect, even though design requirements may at times be opposed. In order to determine opportunities and limits of global approach, problems related to visual and acoustic comfort assessment were examined for a baroque church in Italy.

Pages