Servicing the Millennium Dome.

With a diameter of 320m, and a height of 50m the Millennium Dome is one of the World's largest enclosed spaces, probably the largest among those intended for public use. This paper briefly discusses some of the Building Services issues involved in the design and construction of the Dome, concentrating on the ventilation, and heating/cooling of the building. Buro Happold are the engineers for the Dome responsible for Structural, Building Services, Fire and Access Engineering of the main structure and many of the exhibitions within it.

Reduction of microorganisms by HVAC system filters and analysis of the microorganisms passing through the filters.

k order to determine the amount of micro-organism present before and after the filters ofHVAC systems, 6 systems in 5 buildings were monitored every 2 weeks for one year. Measurementswere taken in triplicate and simultaneously before and after the filters using a sixstage Andersen sampler.

Pressurisation tests of selected apartments as a base for analysis of natural ventilation in multifamily building.

The paper presents a study on application of pressurisation tests of selected apartments as a base for analysis of natural ventilation in multi-family building. The analysis has been performed for 5-floor building constructed in late sixties. 10 apartments from a total number of 45 have been selected for pressurisation tests. The discussion presents estimations of windows' air tightness, the influence of additional air sealing on windows' infiltration coefficient and flow rates at reference conditions.

Particle concentrations in an air conditioned office building with normal and high efficiency filtration.

Indoor and outdoor particle concentrations and ventilation rates were measured versus time ina large office building without tobacco smoking. Periodically, high efficiency filters replacedthe normal filters in air handling systems. For all particle sizes, indoor concentrations variedconsiderably with time. Even with the normal air filters, which have a low efficiency forsubmicron particles, number concentrations of submicron particles were a factor of three tosix smaller indoors compared to outdoors.

Ozone removal by charcoal filters after continuous extensive use (5 to 8 years).

This paper presents ozone removal efficiencies, measured over an extended period of time, inthree different settings: a test plenum, an air handler providing outdoor air to a Class 100cleanroom, and a plenum downstream of an air handler providing outside air to a second, smallerClass 100 cleanroom. In each of these settings, the initial ozone-removal efficiencies werecomparable. After 8 years of service, the charcoal filters servicing the first cleanroom wereremoving about 60% of the ozone in the airstream.

Natural ventilation design using loop equations.

The design of natural ventilation systems - the configuration and sizing of system components - assumes one of two generic forms: the nasty form based on thermal comfort criteria or the nice form based on specified airflow rates. The nasty form demands consideration of the complex coupled interaction of a building's airflow and thermal systems - a difficult and often intractable challenge. The nice form, on the other hand, is quite tractable, yet it is commonly approached using interactive and approximate techniques.

Monitoring indoor relative humidity fluctuations associated with intermittent operation of air conditioners.

In residential buildings, air-conditioners are usually operated in intermittent mode. Thisintermittent mode may complicate many aspects of indoor environments. Indoor humidityexcess is a major problem, since humidity excess is associated with biological pollution andformaldehyde emission. This paper reports our monitoring of indoor air temperature andrelative humidity in a real life building in the hot humid Hong Kong climate. These monitoredresults indicate that, in residential buildings, occupants habits in using windows for naturalventilation exacerbate indoor relative humidity excess.

Limits of natural ventilation through windows in office buildings.

Many HVAC systems built in the time between 1960 and 1980 have now reached the end oftheir lifetime and require retrofitting. When HVAC retrofits are performed in connection withbuilding renovation, there is often a potential for reduction of thermal loads. The questionwhether a renovated building should have an airconditioning plant or free ventilation oftenrevolves around arguments of energy consumption and investment. However it is not takeninto account that there can be no thermal comfort in many cases of cooling loads and outdoortemperatures.

Infiltration and ventilation measurements on three electrically heated multifamily buildings.

In recent years, increasing importance has been placed on energy efficiency in residentialbuildings. This has resulted in tighter buildings, which raises concerns about the amount ofventilation required to provide acceptable indoor air quality. Relatively few studies have beenconducted on multifamily buildings, where the multiple zone interaction makes testing andanalysis difficult. In order to address this problem, detailed testing of air flows, pressures, andtemperatures was done at three electrically-heated multifamily buildings in the U.S.

Indoor air quality in museums and historical buildings in St Petersburg and in north-west region of Russia.

This presentation deals with the problem of achieving stable microclimate in old buildings ofSt Petersburg - such as churches, museums and palaces. Characteristic traits of such buildingsare rather thick envelops which as a rule accumulate large quantities of heat or cold. Themajority of these buildings are equipped only with central water heating and are naturallyventilated.Experimental study of microclimate in buildings of this kind proves that during cold season(with average temperature -10C) the relative humidity there will be about 30-35% and less.