Airbase

AIRBASE is the Bibliographic Database of the AIVC. It contains publications and abstracts of articles related to energy efficient ventilation. Where possible, sufficient detail is supplied in the bibliographic details for users to trace and order the material via their own libraries. Topics include: ventilation strategies, design and retrofit methods, calculation techniques, standards and regulations, measurement methods, indoor air quality and energy implications etc. Entries are based on articles and reports published in journals, internal publications and research reports, produced both by university departments and by building research institutions throughout the world. AIRBASE has grown and evolved over many years (1979 to present day, over 22000 references and 16000 documents available online). For most of the references, the full document is also available online.

The AIVC website includes a protected content feature that provides access to AIRBASE. Access to the protected content is free of charge but requires you to register first.


 
With correct application of vapour barriers the ventilation of building structures is in general not necessary, unless such barriers prevent the escape of trapped moisture from moisture-sensitive - especially organic - materials.
Stichting Bouwresearch
50 occupants of terraced houses, divided into 4 groups, were surveyed three times in October 1981, February 1983 and March 1983. The first group had Isolair air heating and ventilating systems, and were well insulated with double glazing.
Van Dongen J E F.
Discusses reasons behind occupant ventilating behaviour, such as: 1. general attitudes, particularly regarding energy, 2. occupant requirements, 3. components of the habitat micro-climate, 4. optimum micro-climate and desired micro-climate, 5.
Lorimy N, Vezin C.
Reviews the present state of development of dynamic insulation systems. Describes the advantages and disadvantages and assesses probable applications. Earlier articles and reports on dynamic insulation are listed and commented on.
Sodergren D., Fagerstedt A.
Discusses insulation of lofts, roofs, walls, windows and floors, natural ventilation of dwellings and mechanical ventilation with heat recovery in dwellings.
Pezzey J.
Ventilation heat losses have been investigated in an experimental low energy house with active and passive solar energy use and an auxiliary heater.
Hoffmann W.
Reports on use of supply and exhaust ventilation with heat recovery in prefabricated houses and multi-storey buildings.
Petzold H.
From a hygienic viewpoint, optimum indoor air quality can be characterized as the complete absence of pollutants.
Wegner J.
Retrofitting of older buildings brings about a noticeable drop in air supply. Fireplaces in buildings need sufficient combustion air. Tight windows may cause insufficient air supply.
Hoss A, Schrameyer A.
This report focuses on the repair and upgrading of existing windows to acceptable levels of air and thermal resistance.
Iobst J, et al.
This report addresses the factors causing water vapour problems and provides insights into the solutions available with particular emphasis on vapour barrier paints. Concludes that 1.
Iobst J.
Describes air sealing of existing homes by sealants, weatherstripping, air-vapour barriers, and other techniques. Discusses principles of air exchange, moisture movement, air sealing, control of indoor air quality, and combustion air.
Marbek Resource Consultants
The air change rate and the volume of heated air of the villa were measured by the constant concentration tracer gas method during a period of 11 days. The total volume of the villa is 1000 m3 and the heated volume 530 m3.
Roulet C-A, Scartezzini J-L
Describes a project for the design, construction and evaluation of a mechanical ventilation system of small dimensions, easy installation and extreme simplicity.
Piana M, Flisi U, Bolognese L, et al.
Reports on project designed to illustrate building and ventilation solutions which are or which can be expected to reduce the radon daughter content in indoor air in existing buildings or to prevent excessive radon daughter contents in newly-
Clavensjo B, Kumlin H
The Alberta Home Heating Facility has been used over a five year period to attempt to understand the effects of retrofit procedures on the house structure as a whole.
Ackerman M Y, Dale J D, Forest T W, et al.
This report describes tracer gas measurements and pressurization tests made on two low-cost houses about one year after their construction.
Caluwaerts P, Wouters P, L'Heureux D
A pilot test series has been performed to study the possibility of using carbon dioxide produced by the burners of a test furnace as a tracer gas to measure the fire gas leakage of door assemblies.
Ahonen A, Loikkanen P
A method has been introduced for the analysis of the hygrothermal behaviour of building materials and construction. The model equations for coupled heat and mass transfer used in the computer code TRATMO and in the determination of hygrotherm
Kohonen R
A method to analyze thermal and moisture physical behaviour of building components under transient conditions is introduced.
Kohonen R

Pages